GFS Chemicals, Inc.
Columbus, Ohio 43223
LOT ANALYSIS
ITEM: 1232 ACETONE, DISTILLED IN GLASS LOT#:C250708
   
SPECIFICATIONS (MAX. LIMITS OR AS SPECIFIED) PASS/FAIL NUMERICAL RESULT
1. Assay (by GC, corrected for water) 99.7% PASS 99.99%
2. Water 0.5% PASS 0.18%
3. Chlorinated hydrocarbon residue 10 pg/ml PASS <10 pg/ml
4. Residue after evaporation 0.0003% PASS <0.0003%
5. Titrable acid 0.0005 meq/g PASS <0.0005 meq/g
6. Titrable base 0.0006 meq/g PASS <0.0006 meq/g
7. Aldehyde (as HCHO) 0.002% PASS <0.002%
8. Color 10 max PASS <10
9. Methanol 0.05% PASS <0.05%
10. Isopropanol 0.05% PASS <0.05%
11. Substances reducing permanganate Pass Test PASS Passes Test
 
TRACEABLE TO N.I.S.T. (Y/N)? Y
Comment: 
Reported by: Karen Hirsch QC Supervisor: Joan Plowman
Quality Assured to Retest Point: 60 months from shipment
C/A Print Date:  
 
Not for direct use in food, cosmetics, finished pharmaceuticals or drug products. Supplier is not responsible for compliance with FDA Current Good Manufacturing Practice (CGMP) requirements, including without limitation those for finished drug products in 21 C.F.R Parts 210 and 211. Consult warranty limitations at www.gfschemicals.com/statics/documents/aboutus/termsandconditions.html
For resale by GFS authorized distributors only.